PAL16C1 PAL DESIGN SPECIFICATION P7032 BIRKNER/COLI 07/12/81 BETWEEN LIMITS COMPARATOR/LOGIC MMI SUNNYVALE, CALIFORNIA /EQ1U /LT1L /EQ1L /GT2U /EQ2U /LT2L /EQ2L /GT3U /EQ3U GND /LT3L /EQ3L NC NC BTWL OUTL /GT0U /LT0L /GT1U VCC /BTWL = GT3U ;GT CR-3U + EQ3U * GT2U ;EQ CR-3U, GT CR-2U + EQ3U * EQ2U * GT1U ;EQ CR-3U, EQ CR-2U, GT CR-1U + EQ3U * EQ2U * EQ1U * GT0U ;EQ CR-3U, EQ CR-2U, EQ CR-1U, GT CR-0U + LT3L ;LT CR-3L + EQ3L * LT2L ;EQ CR-3L, LT CR-2L + EQ3L * EQ2L * LT1L ;EQ CR-3L, EQ CR-2L, LT CR-1L + EQ3L * EQ2L * EQ1L * LT0L ;EQ CR-3L, EQ CR-2L, EQ CR-1L, LT CR-0L FUNCTION TABLE GT3U EQ3U EQ3L LT3L GT2U EQ2U EQ2L LT2L GT1U EQ1U EQ1L LT1L GT0U LT0L OUTL BTWL ; COMPARATOR REGISTERS ;CR-3 CR-2 CR-1 CR-0 ;GEEL GEEL GEEL G L ;TQQT TQQT TQQT T T OUTPUTS ;UULL UULL UULL U L OUTL BTWL COMMENTS ----------------------------------------------------------------- HLLL XXXX XXXX X X H L OUT OF LIMITS (GT3U=H) LHLL HLLL XXXX X X H L OUT OF LIMITS (GT2U=H) LHLL LHLL HLLL X X H L OUT OF LIMITS (GT1U=H) LHLL LHLL LHLL H L H L OUT OF LIMITS (GT0U=H) LHLL LHLL LHLL L H L H BETWEEN LIMITS LHLL LHLL LLHL X X L H BETWEEN LIMITS LHLL LHLL LLLH X X L H BETWEEN LIMITS LHLL LLHL XXXX X X L H BETWEEN LIMITS LHLL LLLH XXXX X X L H BETWEEN LIMITS LLHL HLLL XXXX X X L H BETWEEN LIMITS LLHL LHLL XXXX X X L H BETWEEN LIMITS LLHL LLHL HLLL X X L H BETWEEN LIMITS LLHL LLHL LHLL X X L H BETWEEN LIMITS LLHL LLHL LLHL H L L H BETWEEN LIMITS LLHL LLHL LLHL L H H L OUT OF LIMITS (LT0L=H) LLHL LLHL LLLH X X H L OUT OF LIMITS (LT1L=H) LLHL LLLH XXXX X X H L OUT OF LIMITS (LT2L=H) LLLH XXXX XXXX X X H L OUT OF LIMITS (LT3L=H) ----------------------------------------------------------------- DESCRIPTION THE BETWEEN LIMITS LOGIC CHECKS THE LT, EQ, AND GT STATUS FROM THE COMPARATOR REGISTERS TO DETERMINE IF THE DATA IS BETWEEN THE UPPER AND LOWER LIMITS LOADED IN THE COMPARATOR REGISTERS. BOTH BETWEEN LIMITS (BTWL) AND OUT OF LIMITS (OUTL) OUTPUTS ARE PROVIDED.